Search History
You May Also Like
Cause and Solution

No Power

1. Power switch not turned on:

Open the cabinet and turn on the power switch inside the distribution box.

 

2. Blown fuse:

Replace the fuse (spec: 500V/10A).

 

3. Power indicator light not on:

Replace the power switch. 

Oil Injector Does Not Return to Stop Position

Positioning switch damaged:

Replace the positioning switch. 

No Oil Production / Inaccurate Oil Filling

1. Oil tank empty:

Refill oil or replace the oil tank.


2. The intake pipe is damaged:

Replace the feed pipe.


3. The injector is leaking:

Clean the oiler or replace the seal.


4. Insufficient heating / Thermostat malfunction:

Adjust temperature settings or replace the thermostat.    